EM613002 Din Rail DC Meter NB-IOT Energy Meter for DC System

1. Brief introductionEM series include AC meter and DC meter. There are 2 models of DC Din rail meter : EM613001 & EM613002.Generally AC energy meters are used for measuring alter-current while DC met...

EM613002 Din Rail DC Meter NB-IOT Energy Meter for DC System
  • EM613002 Din Rail DC Meter NB-IOT Energy Meter for DC System
4
  • Product Details
  • 1. Brief introduction

    EM series include AC meter and DC meter. There are 2 models of DC Din rail meter : EM613001 & EM613002. they can be used for dc system remote monitoring.Generally AC energy meters are used for measuring alter-current while DC meter are used to measure direct current. It’s worth to highlight that RS485 & NB-IOT communication are optional. As a NB-IOT DC Energy Meter, this meter can be applied to New Energy Area, like Solar System and EV Charger (Electric Car). It can also be used as a DCU with multiple EM613001 to serve as a sub-metering system.

    375V DC meter, LVDC meter, LV DC power meter, DC electric meter.png


    2.Function Description

    1. Shunt Sampling for DC Measuring, Class 1

    2. Measure I, V, kWh (10~240A, 40~400VDC)

    3. RS485 Communication with DTL645 Protocol

    4. Over-current/voltage Alarm (Programmable)

    5. LCD Backlight, Four Tariffs with 8 Time Slots


    3. Specifications

    M-20200508068

    NB-IOT DC Solar Energy Meter

    Reference voltage

    DC40V-400V

    Current

    10~240A

    Operation temp.

    -20℃~+70℃

    Accuracy class

    Cl.1.0

    Average humidity

    75%

    Relative humidity

    95%

    Communication

    RS485 & NB-IOT Communication

    Communication protocol

    DTL645

    Impulse constant

    100 imp/kWh

    LCD display

    LCD 6+2

    Power consumption

    ≤0.4W,≤8VA

    Standard compliant